Код на продукта | ARK1004 |
---|---|
Марка | Bausch & Lomb |
Произведено | 2015 |
Състояние | Употребяван |
Гаранция | 6 месеца (има опция за удължаване -виж често задавани въпроси) |
Местоположение | Arkmed Store – Kardzhali/Bulgaria |
ДДС | Без |
ДДС инфо | ДДС не се начислява в ЕС, а за останалите страни ставката е 20%. |
Транспорт | Без |
Доставка и разходи за обучение | Моля, свържете се с нас |
Technical Specifications
Dimensions | |
Height | 48 in (122 cm) |
Width | 18 in (45.7 cm) |
Depth | 18 in (45.7 cm) |
Weight | 230 Ibs (114 kg) |
Display | |
Type | Flat Panel, TFT LCD Full Color |
Size | 19″ (48.2 cm) Diagonal |
Pixels | 1280 x 1024 |
Tilt | ±15° up and -10° down |
Swivel | ±90° |
Aspiration | |
General | Provides Cassette Full, Near-Full and Continuous Fluid Level Sensing. Programmable vacuum response curves. |
Modes of Operation | Linear control of vacuum. Fixed, Onn/Off control of vacuum. Dual Linear Modes: Pitch or Yaw. |
Operating Parameters | I/A mode: 0 mmHg to 600 mmHg;
Phaco: 10 mmHg to 600 mmHg; Vitrectomy: 0 mmHg to 600 mmHg; Extrude: 0 mmHg to 600 mmHg; Vacuum Control: 1 mmHg increments |
Irrigation | Gravity feed from I/V bottle with pinch valve On/Off control via footpedal |
Reflux | Control: Gravity feed from I/V bottle; Modes: Continuous, Pulsed; Activated via the Foot Control |
Vitrectomy | |
Linear Cut Rate Mode Operating Paramters | Range: 30 to 5000 cuts per minute in 1 cut per minute increments;
Control: Linear control of cut rate via the footpedal |
Fixed Cut Rate Mode Operating Paramters | Range: 30 to 5000 cuts per minute in 1 cut per minute increments; Cut rate is derated no more than 20% above 3000 feet (915 meters) altitude;
Control: On/Off control of cut via the footpedal |
Ultrasoun Functions | |
Programming Levels 1,2,3 | Continuous ultrasound; Pulsed ultrasound; Fixed pulse ultrasound; Single burst ultrasound; Multiple burst ultrasound |
Programming Level 3 only | Dual Linear Ultrasoun; Linear Power, Linear Pulse ultrasound; Linear Power, Linear Duty Cycle ultrasound; Dual Linear Multiple Burst ultrasound; Variable Power Multiple Burst ultrasound; Variable Power Linear Burst ultrasound |
Viscous Fluid Controls | |
Injection Mode Pressure | 70 psi (482.6 kPA, 4.8 bar) |
Extraction Mode Vacuum | Between 5 to 600 mmHg in 10 mmHg increments |
Fluid Ait Exchange | |
Outpu | 0.1 micron hyrophobic filtered air |
Pressure | 150 mmHg maximum air pressure |
Flow Rate | Up to 4.8 standard cubic feet per hour (2.25 L/min) |
Safety | System includes pneumatic shut-off valve in case of power loss |
Ullumination | |
Modes of Operation | Independent Ullumation and control of either port |
Lamp Type | Xenon and Xenon-Mercury |
Output | Light output from a single port is minimum 25 lumens using standard 20g probe. |
Safety Filter | Both ports incorporate permanent filtration to reduce ultraviolet, violet, deep red and infrared light |
Control | 0 – 100% control range, 1% resolution |
Color Filtration | None, Green, Yellow, Amber (only available on Port 1 when a xenon lamp is installed) |